EMR MPE standards compliance evaluation tool

EMR MPE standards compliance evaluation tool usage notes

Title

Antenna

PEP input (W)
(0-**)
Frequency (MHz)
(1-300000)

Gain (dBi) MPE standard
Ground reflection (+4dB) Extra margin (dB)

Modulation

Mod Type Mod Factor (%)
(0-100)
Transmitter on (s)
(0-**)
Transmitter off (s)
(0-**)

Scenarios

Comment Relative
field strength (pu)
(0-**)
Aperture
diagonal (m)
(0-**)
C
A

  

  HF Tx Po=90W PEP on 7.1MHz, 15m RG-58C/U to a ground mounted quarter wave vertical, VSWR =1.5, SSB voice modulation.

  VHF Tx Po=50 PEP on 146MHz, 50m LDF4-50 to a Yagi, VSWR =1.25, FM voice modulation.

  GSM 850 BTS Tx Po=25W PEP on 850MHz, 0dB feed loss, 15dBi panel, CW (conservative model).

This calculator implements the methods and radiation thresholds described in:

Some useful links:

This page requires your browser supports Javascript 1.1, which is available in Netscape 3.0x and later; and MSIE 4.0x and later. If the calculator is not working for you, check that you have Javascript enabled. 

V1.02. Use at your own risk, not warranted for any purpose. Do not depend on any results without independent verification.

CVS: $Id: emrcc.php,v 1.4 2007/01/02 00:38:01 owen Exp $


Other VK1OD tools.

I appreciate your comments on this web, and advice of problems that you may have encountered. Try the Feedback form.

© Copyright: Owen Duffy 1995, 2001. All rights reserved.